ProStat Opti-Klens OK-IIE Lab Face & Eyewash with Eliminator Valve – 7160
The ProStat Opti-Klens OK-IIE Lab 7160 is a faucet-mounted emergency eye and face wash with Eliminator Valve designed specifically for compatible laboratory gooseneck faucets. The chrome-plated solid brass unit uses two upward-curving spray nozzles with a greater forward angle than the standard OK-IIE, helping accommodate the geometry of laboratory faucet installations.
- Model: OK-IIE Lab with Eliminator Valve
- Application: Emergency eye and face flushing
- Flow Rate: More than 3 GPM
- Construction: Chrome-plated solid brass
- Installation: Compatible laboratory gooseneck faucet; no separate eyewash plumbing required
ProStat Item #: 7160 | Model: OK-IIE Lab | Coverage: Eyes & Face | Mount: Lab Faucet
ProStat Opti-Klens OK-IIE Lab 7160 Face & Eyewash with Eliminator Valve
The ProStat Opti-Klens OK-IIE Lab 7160 is a faucet-mounted emergency eye and face wash designed specifically for compatible laboratory gooseneck faucets. It provides broader eye and facial flushing coverage while using the laboratory sink's existing water supply.
The Lab model differs from the standard OK-IIE primarily in its spray geometry. ProStat specifies that the two spray nozzles curve upward at a 15-degree greater angle than the standard OK-II model, helping position the flushing streams appropriately for laboratory-style gooseneck faucet installations.
Key Features & Benefits
- Eye and face flushing: Designed for emergency flushing of both the eyes and surrounding facial area.
- Laboratory faucet configuration: Designed specifically for compatible gooseneck-style laboratory faucets.
- 15-degree greater spray angle: Nozzles curve upward at a greater angle than the standard OK-II configuration.
- More than 3 GPM flow: ProStat specifies a flow rate greater than 3 gallons per minute.
- Eliminator Valve included: Allows the hot and cold faucet settings to remain preset while normal sink flow is controlled separately.
- Continuous water supply: Uses the building's existing water supply rather than a limited portable reservoir.
- Chrome-plated solid brass: Durable construction for permanent installation.
- Hands-free emergency flushing: Allows the user to use both hands to help hold the eyelids open during flushing.
- No separate eyewash plumbing: Installs on a compatible laboratory faucet without requiring a separate eyewash water connection.
- Two faucet adapters included: Supplied with two commonly used adapters for compatible faucet installations.
ProStat Opti-Klens OK-IIE Lab 7160 Specifications
| Brand: | ProStat First Aid |
| SKU / Ordering Number: | 7160 |
| Model: | OK-IIE Lab |
| Product Type: | Faucet-Mounted Emergency Eye/Face Wash |
| Coverage: | Eyes & Face |
| Valve: | Eliminator Valve |
| Flow Rate: | More than 3 GPM |
| Spray Configuration: | Two Upward-Curving Spray Nozzles |
| Spray Angle: | 15° Greater Than Standard OK-II |
| Construction: | Chrome-Plated Solid Brass |
| Water Supply: | Existing Faucet / Continuous Water Supply |
| Faucet Type: | Compatible Laboratory Gooseneck Faucet |
| Adapters Included: | Two Common Faucet Adapters |
Designed for Laboratory Gooseneck Faucets
The defining feature of the OK-IIE Lab 7160 is its laboratory-specific spray geometry. ProStat designed the Lab configuration for compatible gooseneck faucets rather than conventional standard faucets.
Its two spray nozzles curve upward at a 15-degree greater angle than the standard OK-II configuration. This additional forward angle helps position the flushing streams more appropriately when the unit is installed on a laboratory faucet.
Eye & Face Flushing with More Than 3 GPM
The OK-IIE Lab is an eye and face wash, not an eye-only eyewash. ProStat specifies that the laboratory face/eyewash configuration delivers more than 3 gallons per minute.
This higher-flow, two-nozzle configuration provides broader flushing coverage than the OK-IE 7158 eye-only model and is intended for applications where both eye and facial exposure may need to be addressed.
How the Opti-Klens Eliminator Valve Works
The Eliminator Valve allows the laboratory faucet's hot and cold settings to remain preset while normal sink flow is controlled separately through the valve. This helps reduce the need to repeatedly readjust the faucet controls during routine sink use.
The sink can continue to be used for normal laboratory work while the Opti-Klens remains installed and available for emergency flushing.
Why Select Safety Sales Offers the Eliminator Valve Models
Select Safety Sales offers the three ProStat Opti-Klens configurations equipped with the Eliminator Valve: the OK-IE 7158, OK-IIE 7159 and OK-IIE Lab 7160.
This provides a consistent lineup for facilities that want faucet-mounted eyewash equipment while maintaining separate control of normal sink flow without continually readjusting the hot and cold faucet settings.
Continuous Water Supply Without a Separate Eyewash Fixture
The OK-IIE Lab uses the building's existing water supply rather than a self-contained reservoir. When properly installed on a compatible laboratory faucet, it provides continuous emergency flushing water without requiring a separate portable eyewash tank.
The faucet-mounted configuration also keeps the eyewash integrated with an existing sink location rather than requiring a separate freestanding or wall-mounted fixture.
OK-IIE Lab vs. OK-IIE Regular
Both the OK-IIE 7159 and OK-IIE Lab 7160 provide eye and face flushing and deliver more than 3 GPM. The primary difference is the faucet configuration and spray angle.
The 7159 is intended for compatible standard faucets. The 7160 Lab version is intended for compatible laboratory gooseneck faucets and uses the greater forward spray angle needed for that installation style.
Which Opti-Klens Eliminator Valve Model Do I Need?
The primary differences among the three Opti-Klens Eliminator Valve models are flushing coverage and faucet configuration.
| Model | Item # | Coverage | Application |
|---|---|---|---|
| OK-IE | 7158 | Eyes | Compatible standard faucet; eye-only flushing |
| OK-IIE | 7159 | Eyes & Face | Compatible standard faucet; eye and face flushing |
| OK-IIE Lab | 7160 | Eyes & Face | Compatible laboratory gooseneck faucet |
Where Is the ProStat OK-IIE Lab 7160 Best Used?
- Research laboratories
- Educational science laboratories
- Healthcare and clinical laboratories
- Industrial laboratories
- Quality-control and testing areas
- Workplaces using compatible laboratory gooseneck faucets where both eye and facial flushing may be required
Is the OK-IIE Lab 7160 Right for Your Facility?
Choose the OK-IIE Lab 7160 when the application requires eye and face flushing from a compatible laboratory gooseneck faucet. Its greater forward spray angle is the primary feature that distinguishes it from the standard OK-IIE 7159.
For a compatible standard faucet, choose the OK-IIE 7159. If the application requires eye-only flushing rather than eye and face coverage, consider the more compact OK-IE 7158.
Install and maintain the Opti-Klens according to ProStat's instructions and verify faucet compatibility before installation. Emergency eyewash compliance depends on the complete installation, including the workplace hazard, location, accessibility, water supply, flushing temperature, activation and other applicable requirements. Purchasing an eyewash device alone does not make an installation compliant.
Frequently Asked Questions
What is the ProStat OK-IIE Lab 7160?
The OK-IIE Lab 7160 is ProStat's Opti-Klens faucet-mounted eye and face wash for compatible laboratory gooseneck faucets, supplied with the Eliminator Valve.
How much water does the OK-IIE Lab provide?
ProStat specifies a flow rate of more than 3 gallons per minute for the laboratory face and eyewash configuration.
What is the difference between the OK-IIE 7159 and OK-IIE Lab 7160?
The OK-IIE 7159 is designed for compatible standard faucets. The OK-IIE Lab 7160 is designed for compatible laboratory gooseneck faucets and uses spray nozzles with a 15-degree greater angle than the standard OK-II configuration.
Does the OK-IIE Lab flush both the eyes and face?
Yes. The OK-IIE Lab is designed as an eye and face wash, providing broader flushing coverage than the eye-only OK-IE 7158.
What does the Eliminator Valve do?
The Eliminator Valve allows the faucet's hot and cold settings to remain preset while normal sink water flow is controlled separately.
Does the OK-IIE Lab require separate eyewash plumbing?
No separate eyewash plumbing connection is required. The unit installs on a compatible laboratory faucet and uses the sink's existing water supply.
Does the OK-IIE Lab include faucet adapters?
Yes. ProStat states that two commonly used faucet adapters are supplied with the unit, with other adapters available for additional compatible faucet configurations.
Customer Reviews




(0.00)stars out of 5